Aircom Premium koaksialkabel 202m lavtap 50 Ohm
Design:
• Inner conductor: hybrid aluminium core Ø 2,75 mm (0,108 in dia)
• Insulation of foamed Polyethylene (PE) with skin Ø 7,20 mm (0,283 in dia)
• Bonded copper foil overlapped, applied longitudinally
• Shield braiding of bare copper wires 0.15mm dia (35 AWG)
• Coverage about 75% Ø 7,90 mm (0,311 in dia)
Jacket:
• Polyvinylchloride (PVC) BK
• Wall thickness about 1.1mm Ø (10,2 ±0,3) mm (0,402 ±0,012 in dia)
Electrical data at 20°C
• Conductor resistance = 5 Ohm/km
• Insulation resistance = 10 GOhm*km
• Characteristic impedance (50±3) Ohm
• Capacitance (1 kHz) 78 nF/km
• Screening attenuation 1 GHz (DIN EN 50289-1-6 / triaxial method) = 90 dB
• Relative velocity of propagation 85 %
• Test voltage (wire/screen rms 50Hz 1 min) 1000 V
Frequency (MHz) |
10 |
100 |
500 |
1000 |
2000 |
2400 |
3000 |
4000 |
5000 |
6000 |
8000 |
10000 |
12000 |
Attenuation typ. (dB/100m) |
1,1 |
3,6 |
8,5 |
12,5 |
18,2 |
20 |
23 |
27 |
31 |
35 |
45 |
60 |
75 |
Mean. Power (W) at 40°C |
4700 |
1400 |
620 |
420 |
290 |
260 |
230 |
190 |
170 |
150 |
130 |
100 |
80 |
Mechanical and thermal characteristics:
Jacket material acc. to DIN EN 50290-2-22 (VDE 0819), compound type TM52 (HD 624,2)
Flame retardant acc. to IEC 60332-1-2
Other characteristics:
RoHS compliant (Directive 2011/65/EC)
Temperature range
Storage, installation and operating: -40°C (-40°F) up to 85°C (185°F)
Min. bending radius allowed: repeated 8x Ø, single 4x Ø
Weight about: 129kg/km (86,5 lb/1000ft)